{"id":75142,"date":"2022-11-15T01:32:18","date_gmt":"2022-11-15T01:32:18","guid":{"rendered":"https:\/\/sunrisephotonics.com\/?page_id=75142"},"modified":"2022-11-15T01:33:54","modified_gmt":"2022-11-15T01:33:54","slug":"75142-2","status":"publish","type":"page","link":"https:\/\/www.sunrisephotonics.com\/single-mode-os2-mpo-to-mpo-fiber-patch-cable-16-fiber.html","title":{"rendered":"Single Mode OS2 MPO to MPO Fiber Patch Cable, 16 Fiber"},"content":{"rendered":"

[vc_row type=”container”][vc_column width=”1\/2″][vc_column_text]The change of TIA-942 has added MPO-16, MPO-32, MPO-24, Cat8 cable, and the longest direct connection cable has been reduced from 10 meters to 7 meters. The data center cabling architecture is developing towards high response, low latency, easy expansion, and multi-routing. Achieving faster network connections requires increasing channel rates, increasing the number of fiber cores, increasing the number of wavelengths, and using better fibers. With the continuous development of cloud computing, the core network of the data center will rapidly evolve to 400G in the future, and the optical fiber network connector must be a parallel development method of LC and MPO.[\/vc_column_text][\/vc_column][vc_column width=”1\/2″][vc_single_image image=”75143″ img_size=”full”][\/vc_column][\/vc_row][vc_row type=”container”][vc_column][vc_column_text]<\/p>\n

\n\n\n\n\n\n\n\n\n\n
Fiber Type<\/strong><\/td>\n9\/125\u00b5m Singlemode OS2<\/td>\nFiber Count<\/strong><\/td>\n16-Fiber<\/td>\n<\/tr>\n
Connector Type<\/strong><\/td>\nMPO Female to MPO Female<\/td>\nPolish<\/strong><\/td>\nAPC to APC<\/td>\n<\/tr>\n
Cable Length <\/strong><\/td>\n1m,2m,3m \u2026 500m or Customize<\/td>\nCable Diameter<\/strong><\/td>\n3.0 mm<\/td>\n<\/tr>\n
Insertion Loss<\/strong><\/td>\n\u22640.7dB<\/td>\nReturn Loss<\/strong><\/td>\n\u226555dB<\/td>\n<\/tr>\n
Polarity<\/strong><\/td>\nType B (Crossover)<\/td>\nDurability<\/strong><\/td>\n\u2265200 times<\/td>\n<\/tr>\n
Jacket Material<\/strong><\/td>\nLSZH<\/td>\nJacket Color<\/strong><\/td>\nYellow<\/td>\n<\/tr>\n
Environment<\/strong><\/td>\nOperating: -20\u00b0C to 70\u00b0C
\nStorage: -40\u00b0C to 85\u00b0C<\/td>\n
Application<\/strong><\/td>\nOptical switching interframe connections
\nHigh-density fiber card edge access
\nArray trunk cables
\nData Center Cabling<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n

[\/vc_column_text][vc_column_text]OS2 single mode MPO trunk cable is factory pre-terminated 9\/125 OS2 single mode MPO to MPO cable, which offers the user the advantage of consistent quality, much faster installation, and simpler cable management. The MPO fiber optic trunk cable is manufactured with multiple 16-wire female to female MPO connectors to give 16 core fiber cables. The trunk cable conforms to Method B polarity (Cross-Connect) and the MTP\u00ae connector is available upon request. This MPO trunk cable is suitable for use in 40G QSFP + PIR4, 40G QSFP + PLR4, 100G QSFP28 PSM4, 400G OSFP DR4, 400G OSFP XDR4, 400G QSFP-DD DR4 and 400G QSFP-DD XDR4 parallel transceiver optical connection.<\/p>\n

Features<\/p>\n

\u2022 Factory finished, provide consistent quality, high performance, and reduce installation time
\n\u2022 100% tested for low insertion loss performance and high back reflection
\n\u2022 Fiber count: 16 fiber trunk cable
\n\u2022 Suitable for MPO application
\n\u2022 Singlemode OS2 fiber
\n\u2022 Type B polarity, used for 40G PSM4 QSFP +, 100G PSM4 QSFP28, 400G DR4 \/ XDR4 OSFP or QSFP-DD transceiver module
\n\u2022 Optimized performance – available in elite MPO and discrete premium connector upon request
\n\u2022 Comply with IEC 61754-7, TIA \/ EIA 604-5, Telcordia GR-1435-CORE and RoHS
\n\u2022 LSZH jacket by default[\/vc_column_text][\/vc_column][\/vc_row][vc_row type=”container”][vc_column][vc_column_text]<\/p>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
Part Number<\/strong><\/td>\n Description<\/strong><\/td>\n<\/tr>\n
MPO\/A\/F-MPO\/A\/F-16OS2-xM-B-LSZH<\/td>\n1M 9\/125\u00b5m Single-Mode OS2 MPO Fiber Optic Trunk Cable, 16 Fiber, Female, APC, Polarity B, LSZH<\/td>\n<\/tr>\n
MPO\/A\/F-MPO\/A\/F-16OS2-3M-B-LSZH<\/td>\n3M 9\/125\u00b5m Single-Mode OS2 MPO Fiber Optic Trunk Cable, 16 Fiber, Female, APC, Polarity B, LSZH<\/td>\n<\/tr>\n
MPO\/A\/F-MPO\/A\/F-16OS2-5M-B-LSZH<\/td>\n5M 9\/125\u00b5m Single-Mode OS2 MPO Fiber Optic Trunk Cable, 16 Fiber, Female, APC, Polarity B, LSZH<\/td>\n<\/tr>\n
MPO\/A\/F-MPO\/A\/F-16OS2-7M-B-LSZH<\/td>\n7M 9\/125\u00b5m Single-Mode OS2 MPO Fiber Optic Trunk Cable, 16 Fiber, Female, APC, Polarity B, LSZH<\/td>\n<\/tr>\n
MPO\/A\/F-MPO\/A\/F-16OS2-10M-B-LSZH<\/td>\n10M 9\/125\u00b5m Single-Mode OS2 MPO Fiber Optic Trunk Cable, 16 Fiber, Female, APC, Polarity B, LSZH<\/td>\n<\/tr>\n
MPO\/A\/F-MPO\/A\/F-16OS2-20M-B-LSZH<\/td>\n20M9\/125\u00b5m Single-Mode OS2 MPO Fiber Optic Trunk Cable, 16 Fiber, Female, APC, Polarity B, LSZH<\/td>\n<\/tr>\n
MPO\/A\/F-MPO\/A\/F-16OS2-30M-B-LSZH<\/td>\n30M 9\/125\u00b5m Single-Mode OS2 MPO Fiber Optic Trunk Cable, 16 Fiber, Female, APC, Polarity B, LSZH<\/td>\n<\/tr>\n
MPO\/A\/F-MPO\/A\/F-16OS2-50M-B-LSZH<\/td>\n50M 9\/125\u00b5m Single-Mode OS2 MPO Fiber Optic Trunk Cable, 16 Fiber, Female, APC, Polarity B, LSZH<\/td>\n<\/tr>\n
MPO\/A\/F-MPO\/A\/F-16OS2-70M-B-LSZH<\/td>\n70M 9\/125\u00b5m Single-Mode OS2 MPO Fiber Optic Trunk Cable, 16 Fiber, Female, APC, Polarity B, LSZH<\/td>\n<\/tr>\n
MPO\/A\/F-MPO\/A\/F-16OS2-100M-B-LSZH<\/td>\n100M 9\/125\u00b5m Single-Mode OS2 MPO Fiber Optic Trunk Cable, 16 Fiber, Female, APC, Polarity B, LSZH<\/td>\n<\/tr>\n
MPO\/A\/F-MPO\/A\/F-16OS2-200M-B-LSZH<\/td>\n200M 9\/125\u00b5m Single-Mode OS2 MPO Fiber Optic Trunk Cable, 16 Fiber, Female, APC, Polarity B, LSZH<\/td>\n<\/tr>\n
MPO\/A\/F-MPO\/A\/F-16OS2-500M-B-LSZH<\/td>\n500M 9\/125\u00b5m Single-Mode OS2 MPO Fiber Optic Trunk Cable, 16 Fiber, Female, APC, Polarity B, LSZH<\/td>\n<\/tr>\n
MPO\/A\/F-MPO\/A\/F-16OS2-xM-B-LSZH<\/td>\nCustom Length xM 9\/125\u00b5m Single-Mode OS2 MPO Fiber Optic Trunk Cable, 16 Fiber, Female, APC, Polarity B, LSZH<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n

[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"

[vc_row type=”container”][vc_column width=”1\/2″][vc_column_text]The change of TIA-942 has added MPO-16, MPO-32, MPO-24, Cat8 cable, and the longest direct connection cable has been reduced from 10 meters to 7 meters. The data center cabling architecture is developing towards high response, low latency, easy expansion, and multi-routing. Achieving faster network connections requires increasing channel rates, increasing the number […]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-full-width.php","meta":{"_acf_changed":false,"footnotes":""},"acf":[],"yoast_head":"\nSingle Mode OS2 MPO to MPO Fiber Patch Cable, 16 Fiber - Sunrise Photonics<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.sunrisephotonics.com\/single-mode-os2-mpo-to-mpo-fiber-patch-cable-16-fiber.html\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Single Mode OS2 MPO to MPO Fiber Patch Cable, 16 Fiber - Sunrise Photonics\" \/>\n<meta property=\"og:description\" content=\"[vc_row type=”container”][vc_column width=”1\/2″][vc_column_text]The change of TIA-942 has added MPO-16, MPO-32, MPO-24, Cat8 cable, and the longest direct connection cable has been reduced from 10 meters to 7 meters. The data center cabling architecture is developing towards high response, low latency, easy expansion, and multi-routing. Achieving faster network connections requires increasing channel rates, increasing the number […]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.sunrisephotonics.com\/single-mode-os2-mpo-to-mpo-fiber-patch-cable-16-fiber.html\" \/>\n<meta property=\"og:site_name\" content=\"Sunrise Photonics\" \/>\n<meta property=\"article:modified_time\" content=\"2022-11-15T01:33:54+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.sunrisephotonics.com\/single-mode-os2-mpo-to-mpo-fiber-patch-cable-16-fiber.html\",\"url\":\"https:\/\/www.sunrisephotonics.com\/single-mode-os2-mpo-to-mpo-fiber-patch-cable-16-fiber.html\",\"name\":\"Single Mode OS2 MPO to MPO Fiber Patch Cable, 16 Fiber - Sunrise Photonics\",\"isPartOf\":{\"@id\":\"https:\/\/www.sunrisephotonics.com\/#website\"},\"datePublished\":\"2022-11-15T01:32:18+00:00\",\"dateModified\":\"2022-11-15T01:33:54+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.sunrisephotonics.com\/single-mode-os2-mpo-to-mpo-fiber-patch-cable-16-fiber.html#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.sunrisephotonics.com\/single-mode-os2-mpo-to-mpo-fiber-patch-cable-16-fiber.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.sunrisephotonics.com\/single-mode-os2-mpo-to-mpo-fiber-patch-cable-16-fiber.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.sunrisephotonics.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Single Mode OS2 MPO to MPO Fiber Patch Cable, 16 Fiber\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.sunrisephotonics.com\/#website\",\"url\":\"https:\/\/www.sunrisephotonics.com\/\",\"name\":\"Sunrise Photonics\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.sunrisephotonics.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Single Mode OS2 MPO to MPO Fiber Patch Cable, 16 Fiber - Sunrise Photonics","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.sunrisephotonics.com\/single-mode-os2-mpo-to-mpo-fiber-patch-cable-16-fiber.html","og_locale":"en_US","og_type":"article","og_title":"Single Mode OS2 MPO to MPO Fiber Patch Cable, 16 Fiber - Sunrise Photonics","og_description":"[vc_row type=”container”][vc_column width=”1\/2″][vc_column_text]The change of TIA-942 has added MPO-16, MPO-32, MPO-24, Cat8 cable, and the longest direct connection cable has been reduced from 10 meters to 7 meters. The data center cabling architecture is developing towards high response, low latency, easy expansion, and multi-routing. Achieving faster network connections requires increasing channel rates, increasing the number […]","og_url":"https:\/\/www.sunrisephotonics.com\/single-mode-os2-mpo-to-mpo-fiber-patch-cable-16-fiber.html","og_site_name":"Sunrise Photonics","article_modified_time":"2022-11-15T01:33:54+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.sunrisephotonics.com\/single-mode-os2-mpo-to-mpo-fiber-patch-cable-16-fiber.html","url":"https:\/\/www.sunrisephotonics.com\/single-mode-os2-mpo-to-mpo-fiber-patch-cable-16-fiber.html","name":"Single Mode OS2 MPO to MPO Fiber Patch Cable, 16 Fiber - Sunrise Photonics","isPartOf":{"@id":"https:\/\/www.sunrisephotonics.com\/#website"},"datePublished":"2022-11-15T01:32:18+00:00","dateModified":"2022-11-15T01:33:54+00:00","breadcrumb":{"@id":"https:\/\/www.sunrisephotonics.com\/single-mode-os2-mpo-to-mpo-fiber-patch-cable-16-fiber.html#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.sunrisephotonics.com\/single-mode-os2-mpo-to-mpo-fiber-patch-cable-16-fiber.html"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.sunrisephotonics.com\/single-mode-os2-mpo-to-mpo-fiber-patch-cable-16-fiber.html#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.sunrisephotonics.com\/"},{"@type":"ListItem","position":2,"name":"Single Mode OS2 MPO to MPO Fiber Patch Cable, 16 Fiber"}]},{"@type":"WebSite","@id":"https:\/\/www.sunrisephotonics.com\/#website","url":"https:\/\/www.sunrisephotonics.com\/","name":"Sunrise Photonics","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.sunrisephotonics.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.sunrisephotonics.com\/wp-json\/wp\/v2\/pages\/75142"}],"collection":[{"href":"https:\/\/www.sunrisephotonics.com\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.sunrisephotonics.com\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.sunrisephotonics.com\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.sunrisephotonics.com\/wp-json\/wp\/v2\/comments?post=75142"}],"version-history":[{"count":0,"href":"https:\/\/www.sunrisephotonics.com\/wp-json\/wp\/v2\/pages\/75142\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.sunrisephotonics.com\/wp-json\/wp\/v2\/media?parent=75142"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}